Wind Speed
|
|
Wind Direction
|
|
Wind Alarms
![]() |
|
Wind Speed\Direction Transmitters
|
|
Barometric Pressure
|
|
Air Temperature and Humidity
|
|
RainFall
|
|
Solar Radiation
|
|
Displays & Recorders
|
|
Accessories
|
|
Weather Station
|
|
Electric Power Systems
|
Eurus, Model C47 Single Wind Alarm Monitor
Accuracy: Speed +/- 1 Unit,
Direction +/- 4 degreesEurus WIND ALARM FEATURES:
Alarms have an adjustable filter with time constant of 1-600 seconds to prevent nuisance tripping from wind speed gusts. Current, peak and average wind speed is displayed with user selectable units of miles per hour (MPH), meters per seconds (M/S) or kilometers per hour (KPH). Wind speed measurement timing is crystal controlled for high accuracy.
Four alarms with single pole double throw (SPDT) relays are provided. Each relay is configurable for hysteresis or latch mode operation. The alarms can be individually disabled. In hysteresis mode the alarm is activated when the average wind speed exceeds the closure set point. The alarm remains activated until the average wind speed drops below the opening set point. In latch mode the alarm remains activated until the average wind speed exceeds the closure set point. The alarm remains activated until manually reset.
One or two wind speed circuits are optionally available to provide redundancy in critical applications. Continuity of the anemometer circuit is tested every 10 seconds when the wind is calm. If the circuit fails open or is short circuited, a message is flashed on the display.
Two analog output signals proportional to wind speed are optionally available. The analog output may be ordered with 4-20 mA, 0-1 mA or 0-1 VDC outputs. A screen is provided to simulate wind speed, which allows for system testing and calibration of the optional analog output signals.
All set points and configuration selections are retained in EEPROM memory even when operating power is removed. A back lighted liquid crystal display (LCD) provides excellent readability in bright or low light conditions.
A security code feature resists tampering with set points or control configuration by unauthorized personnel. The control can be ordered for operation from 120 VA., 230 VAC or 12 VDC electrical power. All inputs and analog outputs are protected from damage by high voltage transients with metal oxide varistors. The C47 can be provided to operate with anemometers producing an AC output signal whose frequency is proportional to wind speed. The C47 can also be provided to operate with anemometers whose DC output signal is proportional to wind speed.
One wind direction input is optionally available with one analog output signal proportional to wind direction. The wind vane circuit is continuously monitored for continuity. If an open or short circuit is detected a message is flashed on the LCD screen.
TECHNICAL SPECIFICATION:
| Operating Power: | 105 to 127 VAC, 50/60 Hz 80 - 250 VDC (specify at time of order) |
| Input Device: | A75-104 Three Cup Anemometer (higher performance sensors available) |
| Display: | Liquid Crystal Display 16 characters X 2 Lines. LED Alarm Status Indicators on front panel |
| Controls: | Four button keyboard with tactile and visual feed back |
| Outputs: | Four SPDT Relays, 8 Amps resistive @ 120 VAC Two Analog Wind Speed Outputs One Analog Wind Direction (Azimuth) Output |
| Analog Output Format: | 4-20 ma, 0-1 ma or 0-1V (specify at time of order) |
| Control Accuracy: | Wind Speed +/- 1 Unit Wind Direction +/- 4 degrees |
| Analog Output: | +/-1% of full scale |
| Sensor Accuracy: | See sensor specifications |
| Resolution: | Wind Speed- User selectable 1 MPH, 1 M/S or 1 KPH Azimuth - 2° |
| Connectors: | Barrier strip to accept AWG#12 to AWG@20 copper wire |
| Temperature: | Electronics -20 to +60° C. |
| Sensors: | -55 to +60° C (A75-104 & A75-302) |
| Maintenance: | Check sensor calibration yearly |
| Dimensions: | |
| DIN Package: 1/4 DIN cutout x 5.75" deep NEMA 12 Package: 12"H x 10"W x 6"D NEMA 4X SS Package: 12"H x 10"W x 6"D NEMA 4X FG Package: 12"H x 10"W x 6"D |
|
| Weight: | |
| DIN Package: 2 pounds NEMA 12 Package: 16 pounds NEMA 4X SS Package: 16 pounds NEMA 4X FG Package: 8 pounds |
|
| Accessories: | |
| Thor, Model A96 Surge Protectors Woden, Model A70-LPDD Remote Display Odin, Model A76-T10 Tripod Tower Heated Anemometer Higher Performance Sensors |
|
Product Specification Sheet: Model C47 Wind Alarm
Track Mounted Crane Wind Monitoring Requirment OSHA 1917-45